fbpx

12.5kw Carrier Ducted Inverter 42SHDV125/38SHDV125

544 airconditioning-online1carrierducted
12.5kw Carrier Ducted Inverter 42SHDV125/38SHDV125   12.8kw Cooling Capacity 14.3kw Heating Capacity   Indoor Unit 42SHDV125, Outdoor Unit 38SHDV125, wired controller    Pick up available from Holden Hill, South Australia. Delivery available Australia-Wide. Key features ...Read more
$3,330.00

  • Description
  • Specifications

12.5kw Carrier Ducted Inverter 42SHDV125/38SHDV125

 

12.8kw Cooling Capacity 14.3kw Heating Capacity

 

Indoor Unit 42SHDV125, Outdoor Unit 38SHDV125, wired controller

 

 Pick up available from Holden Hill, South Australia. Delivery available Australia-Wide.

Key features

  • Concealed and flexible installation
  • A high static system allows for more ducts to be installed
  • Single phase which allows for greater flexibility and minimises installation cost
  • Reverse cycle system (heating and cooling)
  • DC inverter system, designed to use electricity efficiently and effectively
  • Quiet operation
  • Easy to install and maintain
  • 5 year warranty

System includes indoor unit, outdoor unit and wired back-lit controller. Ducted systems available to approved trade customers only.

Specifications

Indoor 42SHDV125
Outdoor 38SHDV125
Refrigerant Type   R410A
Power Supply (Volts - Phase - Hz) V / ø / Hz 220-240 / 1 / 50
Cooling Capacity - Rated (Range) kW 12.8 (3.25 - 15)
Efficiency (rated) EER 3.35
Power Input (rated) kW 3.82
Operating Current (rated) A 16.61
Heating Capacity - Rated (Range) kW 14.30 (2.95 - 15.50)
Efficiency (rated) COP 3.70
Power Input (rated) kW 3.86
Operating Current (rated) A 16.87
Indoor Unit Dimensions (WxDxH) mm 380 x 1200 x 625
Net Weight kg 53
Airflow Volume (H) L/s 890
Moisture Removal (cooling) L/Hr 2.90
Fan Motor Output W 560
Sound Pressure (H/M/L) at 1m Distance dBA 50 / 46 / 43
Outdoor Dimensions (WxDxH) mm 1333 x 952 x 410
Net Weight kg 98.5
Compressor Type  -  Twin Rotary
Fan Motor Output W 85x2
Cooling Operating Noise (sound power) (H) dBA(@spl) 69
Heating Operating Noise (sound power) (H) dBA(@spl) 69
Cooling Usable Temperature Range °C -10 to 46
Heating Usable Temperature Range °C -15 to 24
Pipe Size Liquid Line Ø / Gas Line Ø mm / mm 9.52 / 19
Coupler Style  -  Flare
Drain (inside diameter) mm 20
Maximum Length m 50
Chargeless Length m 15
Chargeless Length at 15m from serial numbers m 1505xxxx
Maximum Height Difference m 25